CHARAKTERYSTYKA TECHNICZNA | METODA BADANIA | STANDARD | NEX-GEN |
WYMIARY I WYGLĄD POWIERZCHNI | |||
DŁUGOŚĆ I SZEROKOŚĆ | EN ISO 10545-2 | ±0,6% | +0,02% ~+0,03% |
±2 mm | +0,2 mm | ||
GRUBOŚĆ | EN ISO 10545-2 | ±5% | -2,7% ~+0,2% |
±0,5 mm | -0,3 mm | ||
PROSTOTNOŚĆ BOKÓW | EN ISO 10545-2 | ±0,5% | -0,05% ~+0,02% |
±1,5 mm | -0,28 mm ~ + 0,13 mm | ||
WŁAŚCIWOŚCI FIZYCZNE | |||
ABSORPCJA WODY | EN ISO 10545-3 | ≤0,5% | ≤0,1% |
WYTRZYMAŁOŚĆ | EN ISO 10545-4 | ≥1300N | 2470 |
MODUŁ PĘKNIĘCIA | EN ISO 10545-4 | ≥35 N/mm² | 51 |
ODPORNOŚĆ NA ŚCIERANIE | EN ISO 10545-7 | ZGŁOŚ DO KLASY ŚCIERALNOŚCI | klasa 4 |
PRZEKONANE CYKLE RAPORTÓW | 2100r | ||
ODPORNOŚĆ NA SZOK TERMICZNY | EN ISO 10545-9 | ŻADNA WADA NIE POWINNA BYĆ WIDOCZNA | PRZECHODZIĆ |
ODPORNOŚĆ NA MROŻ | EN ISO 10545-12 | ŻADNYCH WAD POWIERZCHNIOWYCH LUB PĘKNIĘCIA POWINNY BYĆ WIDOCZNE | PRZECHODZIĆ |
SUWAK 96 ANTYPOŚLIZGOWY,BADANIE WAHADŁEM MOKRYM | ZGODNIE Z AS 4586:2013 | - | |
MAT | P3~P4 | ||
WŁAŚCIWOŚCI CHEMICZNE | |||
ODPORNOŚĆ CHEMICZNA DO CHEMII GOSPODARSTWA I SOLE DO BASENÓW | EN ISO 10545-13 | MINIMUM GB | A |
ODPORNOŚĆ NA PLAMOWANIE | EN ISO 10545-14 | KLASA MINIMALNA 3 | KLASA 5 |
SERIA | ROZMIARY | SZT / CTN | M²/ CTN | M²/PLT | CTN/PLT | KG/PLT |
BLUESTONE | 600x600mm/24"x24" | 4 | 1.44 | 57,6 | 40 | 1260 |
300x600mm/12"x24” | 8 | 1.44 | 57,6 | 40 | 1260 | |
600x1200mm/24"x48" | 2 | 1.44 | 36 | 25 | 900 | |
UKŁADARKA 600x600mm/24"x24". | 2 | 0,72 | 28,8 | 40 | 1360 |
*Płytki mogą różnić się rozmiarem, wagą, kolorem, wzorem, żyłkowaniem, fakturą, trwałością, gęstością, powierzchnią i wykończeniem w zależności od partii.Wskaźniki poślizgu służą jako wskazówka i mogą się różnić dla każdej partii płytek.Zaleca się przeprowadzenie nowego testu dla każdej partii płytek, jeśli wymagany jest certyfikat antypoślizgowości.Przedstawione zdjęcia produktów służą wyłącznie celom ilustracyjnym i nie stanowią dokładnego odzwierciedlenia produktu.